Otomatik Transfer Şalterleri

ATyS t M – ATyS g M

From 40 To 160 A

ATyS t M and ATyS g M are three-phase (4P) automatic transfer switches with positive break indication. The ATyS g M is also available in 2P for single phase applications.
The ATyS t M and ATyS g M both include ATyS d M functionality together, with an integrated controller for automatic transfer dedicated to mains/mains applications (ATyS t M) and mains/genset applications (ATyS g M). They are intended for use in low voltage power supply systems where a brief interruption of the load supply is acceptable during transfer.

Advantages
Fast Commissioning

ATyS t M and g M transfer switches offer significant time saving during commissioning (the process takes 2 to 3 minutes). Thanks to the design that allows commissioning through just one potentiometer (4 on the ATyS g M) and four DIP switches, a screwdriver is all that is required to configure the parameters.

ATyS g M: Specifically Designed For Mains/Genset Applications

The ATyS g M integrated controller has been designed to provide specific functions for these applications (genset startup, tests on load…) together with the monitoring of the voltage and frequency of both sources for
three-phase and single-phase networks.

ATyS t M: Specifically Designed For Mains/Mains Applications

The ATyS t M integrated controller has been designed to provide all the functions necessary for these applications (operation with or without priority, preferred source selection) together with the monitoring of the
voltage and frequency of both sources for three-phase networks.

Secured Configuration Settings

In order to prevent any risk of unintended change to the configured settings, a sealable cover is available as an accessory.

ATyS p M

From 40 To 160 A

ATyS p M are single-phase or three-phase automatic transfer switches with positive break indication.
Functions include ATyS t M and ATyS g M capability, with additional programmable parameters and a triggering function. A product model with communication is available. They are intended for use in low voltage power supply systems where a brief interruption of the load supply is acceptable during transfer.

Advantages
Flexible Programming

ATyS p M time delays and inputs/outputs are completely configurable, hence enabling the easy monitoring of specific applications (load shedding, test…) and the definition of an operating cycle specifically adapted to your application.

Trip Function

ATyS p M provides a function for transferring the load to the 0 position in case of loss of both power supply sources (tripping). In this way the load is protected from issues due to source instability.

Communication And Configuration

A specific version of ATyS p M is available with integrated Modbus communication. This gives acces to most product data (status, voltages, frequencies…). A user friendly configuration software is also available free (Easyconfig) to configure, view and save all the parameters in the ATyS p M.

Remote Control İnterface

Specifically designed for installations where the product is enclosed, the remote interface displays product status on the front panel (D10) or displays and controls with access to programming (D20).

ATyS t – ATyS g

125 ile 3200 A Arası

ATyS t and g are three-phase automatic transfer switches, 3 or 4 poles, with positive break indication. They incorporate all the functions offered by the ATyS d, as well as functions intended for mains/mains application (ATyS t) and mains/genset applications (ATyS g).
In automatic mode they enable the monitoring of, and the on load changeover switching between, two power supply sources, in accordance with the parameters configured via two potentiometers and four DIP switches.
They are intended for use in low voltage power supply systems where a brief interruption of the load supply is acceptable during transfer.

Advantages
Rapid Commissioning

ATyS t and g switches offer significant time saving during commissioning (process takes 2 to 3 minutes). Thanks to the design that allows commissioning through just two potentiometers (4 on the ATyS g) and four DIP switches, a screwdriver is all that is required to configure the parameters. For added simplicity, they also offer an autoconfiguration function which enables automatic adjustment of the rated voltage and frequency.

ATyS t: Specifically Designed For Mains/Mains Applications

The ATyS t integrated controller has been designed to provide only the functions required for these applications (operation with or without priority, preferred source selection) together with the monitoring of the voltage and frequency of both sources, for threephase and single-phase networks.

ATyS g: Specifically Designed For Mains/ Genset Applications

The ATyS g integrated controller has been designed to provide specific functions for these applications (genset startup, on-load or off-load tests…) together with the monitoring of the voltage and frequency of both sources for three-phase and single-phase networks.

ATyS p

125 İle 3200 A Arası

ATyS p, konum göstergeli trifaze bir otomatik şalter serisidir.Hem ATyS g tarafından sunulan tüm fonksiyonları hem de güç yönetimi ve haberleşme için tasarlanan fonksiyonları içerirler.
Otomatik modda, butonlar ve bir LCD ekran yoluyla yapılandırılan parametrelere göre iki kaynak arasında izleme ve yük değiştirme anahtarlaması sağlarlar.
Transfer sırasında enerji kesintisinin kabul edilebilir olduğu alçak gerilim güç sistemlerinde kullanım için tasarlanmışlardır.

Avantajları
Olay Kaydı

ATyS p şalterleri, zaman etiketli olay kaydı sayesinde tesisatınızın etkili şekilde izlenmesini sağlar. Haberleşme sistemi yoluyla olaylar geri çağrılabilir ve okunabilir.

Opsiyonel Haberleşme Modülleri

ATyS p, Modbus haberleşmesi için RS485 modülü veya bir Webserver içeren Ethernet modülü gibi opsiyonel modüllerin eklenmesi sayesinde haberleşme fonksiyonları sunar.

Yapılandırma Yazılımı

ATyS p parametrelerinin kolayca yapılandırılmasını ve mevcut yapılandırmanın kaydedilmesini sağlayan bir yazılım (Easyconfig) mevcuttur.

Güç Ölçümleri

ATyS p ürünleri özellikle enerji yönetimi ve izleme için uygundur. Kendi tümleşik güç ve enerji yönetimi işlevlerine ilave olarak, yük seviyesine veya tarifeye göre yük atmayı kontrol etmek için programlanabilir girişler/çıkışlar kullanılabilir.

Jeneratör Periyodik Başlatma Programı (Opsiyon)

ATyS p şalterleri, bakım için ilave işlevler sunar. Başlatma tarihlerinin ve işletim zamanlarınınayarlanmasını mümkün kılan programlıjeneratör başlatma fonksiyonuna sahiptirler.

deneme bonusu veren siteler canlı casino oyunları